Differential pressure based flowmetering for gases, steam and liquids

At systec Controls, deltaflow represents differential pressure (dP) flow measurement—highly precise, reliable, and robust.

The deltaflow family has undergone continuous development for many years. In doing so, we draw not only on our own expertise but also collaborate with renowned institutions such as the Chair of Fluid Mechanics at the University of Erlangen, the Physikalisch-Technische Bundesanstalt (PTB) and the Fraunhofer Institute.

 

deltaflow integrating pitot tube for gas, steam and liquids, pipe diameters from 2mm to 15.000mm

deltaflowC Gas mass flow meter for pipe 2mm to 2000mm

deltafit air mass flow regulator from DN25 to DN400

deltaflow DF12 MMF - Gas/Steam/Liquid flówmeter

DN20 to DN100, incl. multivariable transmitter

Complete probe assembly with stainless steel measuring section (length approx. 10D), featuring a deltaflow DF12 flanged probe, three-way valve manifold, integrated temperature sensor, and multivariable transmitter for mass or standard volumetric flow rate calculation. Includes gaskets and mounting bolts.

deltaflow DF44 MMF - Gas / Steam / Liquid flowmeter

DN200–DN2000, including multivariable transmitter.

Complete averaging pitot tube assembly featuring a weld-in flange connection, counter-support, three-way valve manifold, integrated temperature sensor, and multivariable transmitter for mass or standard volumetric flow rate calculation. Includes gaskets and mounting bolts.

deltaflow DF8 MMF - Gas/Steam/Liquids

DN2 to DN32, including multivariable transmitter.

Complete orifice meter run with three-way valve manifold, integrated temperature sensor, and multivariable transmitter for mass or standard volumetric flow rate calculation. Includes gaskets and mounting screws.

A remarkable deal

deltaflow DF25 MMF - Gas / Steam / Liquid Flowmeter

DN80–DN1000, including multivariable transmitter.